Bio: The Boiler Exhaust Blower are characterized by high efficiency, flat performance curve and wide efficient operation area.
The ventilator is of single suction type.The Boiler Exhaust Blower can be made of right and left - handed two ways.Face forward from one end of the motor. If the impeller rotates clockwise, call it the right fan.Anticlockwise rotation is called left cyclone, represented by "left".The outlet position of the fan is indicated by the outlet Angle of the housing."Left" and "right" can be made into 0 °, 45 °, 90 °, 135 °, 180 °, 225 ° from six angles.
Product performance
Air flow range688~92540m³/h
Pressure range1579~4125Pa
Speed1450~2900r/min
Product details
The Boiler Exhaust Blower is mainly composed of impeller, housing, air inlet, frame, transmission group, adjusting door and so on.
1. The impeller is welded with steel plate between the cone cover, the blade and the plate-shaped wheel, and riveted with the shaft disk to form a whole structure.The impeller runs stably and reliably through static and dynamic balance correction and overspeed experiment.
2. The machine case is a volute integral structure welded by ordinary steel plate.
3. The air inlet is made into a collecting streamlined integral structure, which is bolted to the wall board at the entrance of the housing or the flange of the cover plate.
4. Ventilator and induced draft fan are generally equipped with adjusting door, which is used to adjust the air volume of the device.Damper blade as the petals, outside using transmission structure, flexible rotation, the adjusting range is 90 ° (full close) to 0 ° (full open).From the direction of the air inlet, the position of the adjusting door handle is generally on the right side.The handle of the right-hand fan is pulled up from the bottom to the full open;Left cyclone, handle from top down is fully closed to fully open.
5. The frame is welded with shaped steel.
6. The transmission part is composed of the spindle, coupling and bearing box. The spindle is made of high quality steel and adopts rolling bearing.The bearing box is provided with a thermometer and an oil level indicator.The lube oil adoptsL-AN46 of full-loss system, and the flow rate is determined according to the oil level mark (generally there is no oil when leaving the factory).
Product after-sale
(1) Full-time technical personnel shall cooperate with the user to complete the installation of the fan and conduct a comprehensive review of the fan so that the fan can be installed under normal and ideal conditions.
(2) Within the warranty period, timely repair problems found to users, and remind users to maintain regularly and refueling on time.Maintenance is charged at cost price for customers outside the warranty period.
(3) In case of any malfunction in the operation of the products provided, please contact us by phone. Our company will provide technical Suggestions to solve the problems for users.If the product is damaged due to improper operation, we will provide paid maintenance service.Boiler Centrifugal Fan suppliers
website:http://www.cndjfan.com/centrifugal-fan/boiler-centrifugal-fan/